Radiant heating on the lake.

What makes a good residential HVAC system?

Older houses leaked and, to a degree, are uncomfortable and energy inefficient.  We may think a cold room is standard in houses or a wood boiler needs to heat our house to 26C in the winter. We get use to opening windows in winter to get some fresh air in the house, or even cool […]

Share
Leave a comment Continue Reading →
VAult1 (Medium)

Residential Vault by Uponor

We asked Uponor to put together a residential vault and they responded. We’ll be installing this 6-on setup on a client’s property this spring.

Share
Leave a comment Continue Reading →
AFTER

Adding Cooling to a Hydronic System

A fair amount of our work is not really “geothermal”.  In this case, we are working with an existing boiler hydronic system converted to geothermal. The initial conversion functioned, but had poor climate control.  Heat wasn’t all that adequate with the original staple up PEX spacing and there was no cooling option. So, the plan […]

Share
Leave a comment Continue Reading →
A common water to water heat pump layout for a DES system.

Water to Heat Pump + Fan Coil + Radiant Floor Schematic

This particular posting is a reference drawing on a typical plumbing layout for a water to water heat pump, hydronic fan coil, radiant floor, and domestic hot water support. There are a number of variations likely in the plumbing: – the domestic hot water can be a zone off the initial load plumbing as it […]

Share
Leave a comment Continue Reading →
Short Looping

Short Looping Two Units

This comes up often enough in our work that it is worth a post. When two or more heat pumps are pumped in parallel without thought given to flow, you can run in to some issues.  Look at this figure: If  only one heat pump comes on the flow can go backwards through the second […]

Share
Leave a comment Continue Reading →
textchat

Text Chat

With a very busy fall, we have been travelling a lot and not necessarily working in town. A client was getting worried about his geoexchange air/radiant system as the cold weather approached.  I started off the texting early Saturday morning as I did not want to wake them. I admit I was happy to sort […]

Share
Leave a comment Continue Reading →
10 Circuit Header

10 Ton Header

This is not really about a 10-ton header, this is about the issues one needs to think about in header design. This is a picture of a 10-ton header we built.   Now the header is for a residential property, with a bunch of (expensive) ball valves fused in line. Commercially, an engineer would likely […]

Share
Leave a comment Continue Reading →
20130628_154424[1]

Service Calls

Yes, we take service calls.  There are a lot of geoexchange systems in our area that no longer have the support of the original installer.  I’ll leave it at that. But sometimes we do wish we did not take the call.  Joking.  Just some days you learn more than you want. Here is an example. That […]

Share
Leave a comment Continue Reading →
Mechanical Room Panorama

Mechanical Room Panorama

A recently completed mechanical room with two Waterfurnace water-water heat pumps, Tekmar controls, Wilo loop pump, and the usual mechanics.  This is on 16-18′ of wall space. Apologies for the photo quality as this is a panorama (distortion) taken on a cell phone (lower quality).  

Share
Leave a comment Continue Reading →